MONTPELIER, Vt. (AP) – If an accident at the Vermont Yankee nuclear plant forced operators from the control room, they might have just minutes to use alternate means to shut down the plant before enough water boiled away to expose the highly radioactive core.
At issue now before federal regulators is whether those plant technicians would have enough time. Calculations cited in a recent federal report say it would take 21 minutes for the technicians to shut down the reactor, and – if the plant’s request to boost power by 20 percent is approved – 21.3 minutes for the much feared core exposure to occur.
That’s a margin of 18 seconds.
A quasi-judicial board connected with the Nuclear Regulatory Commission on Wednesday agreed to take at least a passing look at the issue, which was raised in detail in a recent engineering assessment at Vermont Yankee by the NRC staff.
Plant spokesman Robert Williams said Vermont Yankee engineers had done the needed engineering analysis on the core exposure question and had found there to be an adequate safety margin. He said the plant had recently conveyed that finding to the NRC staff and would present it as well to the Atomic Safety and Licensing Board.
“There’s absolutely no problem. The safety is maintained,” Williams said. “We have that capability to shut down the reactor from outside the control room in accordance with the regulation.”
The state Department of Public Service asked the board to look at the core exposure question this past fall. The Atomic Safety and Licensing Board only rules on matters formally put before it, said Jon Block, a Putney lawyer representing the nuclear watchdog group New England Coalition, and wouldn’t have taken notice of a report issued by the NRC staff on Dec. 2.
That report says it is “questionable” whether plant technicians could shut the reactor down from outside the control room before enough water had boiled away to expose the core. To do so, they would need to go to the plant’s “alternate shutdown panels” and activate its “reactor core isolation cooling” system, or RCIC.
In addition, the NRC reported that Vermont Yankee calculated that the time it would have before enough water boiled off to expose the core would be reduced from the current 25.3 minutes to 21.3 minutes if it is allowed to increase the plant’s power output by 20 percent.
The NRC relied on Vermont Yankee’s estimate of the time it would take the core to be exposed; its report made no mention of the agency doing its own calculation. On the other end of the equation – the time it would take to shut the plant down – the NRC found Vermont Yankee unreliable.
The report said inspectors found that Vermont Yankee “had not revised the December 1999 (time estimate of 15 minutes) to reflect the June 2001 time estimate or present day version of the procedure to place the RCIC in service from the alternate shutdown panels.”
The NRC said it wasn’t worried, because at the plant’s current power level, technicians would still have about a four-minute margin between the 21 minutes it took to operate the alternate shutdown panels and the 25.3 minutes it would take for the core to be exposed.
The NRC said the issue was “of very low safety significance” because, “At the 100 percent power level, RCIC could be placed in service from the alternate shutdown panels…”
The NRC report appeared not to address whether the safety significance would increase if the plant were operating at a 120 percent power level, as it is seeking to do, and the time before core exposure were reduced, by Vermont Yankee’s own calculation, to 21.3 minutes.
AP-ES-01-12-05 2035EST